Micrologic 5 and 6 trip units user manual

Powerpact h, j, and lframe circuit breakers trip units. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Powerpact h, j, and lframe trip units schneider electric. Current protection 0 overload and fault indications 4 measurements 5 trip history and pre. Acb,mccb 48049602401cedar rapids, ia, usainstruction bulletinretain for future use. Powerpact h, j, and lframe circuit breakers trip units micrologic 5 6 a or e trip units.

Low voltage electrical distribution compact nsx micrologic 56. Allenbradley micrologix 1500 user manual pdf download. Digital modules for micrologic x control units masterpact mtz. The micrologic plmacs is a device designed to perform measurements on a 3phase electrical power source and load, recording the measurements on a removable sd card with options of transmitting the data in realtime to the user via sms or text messaging. User friendly intuitive use micrologic control units are equipped with a digital lcd display used in conjunction with simple navigation buttons. To learn more, please visit the schneider electric faq. Micrologic trip units are field replaceable to allow for upgrading of the trip unit in the field. For complete information on available circuit breaker models, frame sizes, interrupting ratings, sensor plugs, rating plugs and trip units, see the product catalog.

All electronic trip insulated case circuit breakers are manufactured with a fullfunction trip system. Micrologic trip unit configuration control power the p trip unit is designed to be used with an external 24 vdc power supply. See your programming software user manual for information on programming your micrologix controller. Global english welcome to the schneider electric corporate website. Jan 31, 2018 introducing certain offers of micrologic for our different frames, this video goes over this electronic trip solution available on our molded case powerpact circuit breakers, and on our. Electronic trip motor circuit protectors trip system et 1. Substitution for magnetic and electronic trip units 12. Micrologic trip units built after december of 2005 were improved to meet the ansi and iec emcefi testing standards after complaints of nuisance tripping caused by emcefi events during switching operations. Micrologic trip unit communicating with opc server. The large lcd display used by the p trip unit requires too much current to be powered by current flow through the circuit breaker. You need the modbus communication for micrologic manual, the micrologic control units 5. Tutorial for testing micrologic trip units in both manual and automatic mode using the full function test kit fftk, catalog number s33595, typically used with micrologic trip units installed in. Eolimasterpact nw 25 h1 three pole draw out circuit breaker with micrologic 5. Low voltage electrical distribution masterpact nw circuit breakers and switchdisconnectors from 800 to 6300 a user manual 092009.

Entelliguard tu trip units installation, operation, and maintenance manual ge industrial solutions for ulansi trip units used in the following circuit breakers and switches. Enhanced power measurements functions power quality measurements arequires neutral. Fdm121 display for lv circuit breaker instruction sheet ghd16275 micrologic 5 and 6 trip units for compact nsx circuit breakers user guide lv434103 fr lv434104 en lv434105 es micrologic 5 and 6 trip units for powerpact h, j, and l frame circuit breakers user guide 48940312 en, es, fr micrologic ae trip units user guide. Electronic micrologic 5 6 a or e r c im c i g o l o 2. The universal test set provides three test options for each type of circuit breaker tested. Power quality measurement and advanced protection features. Low voltage compact nsx100 to 630 circuit breakers and switchdisconnectors. Micrologic 5 6 a ammeter or e energy trip units can be used on powerpact h, j, and lframe circuit breakers with performance levels d, g, j, or l. The p trip unit has a circuit voltage power supply which will power the trip. Add your listing here results 21 40 of 352 this category all listings. Micrologic 2, 5 and 6 trip units can be used on any compact nsx circuit breaker. Entelliguard g wavepro ak, akr conversion kits power break power break ii hpc switch, new generation.

For information on the micrologic 5 and 6 trip units, see bulletin. The switch settings menu displays the values at which the switches are set. The table below indicates which devices can be used accord ing to the in rating of the distribution trip units and the circuit breaker size. Micrologic trip units 5 and 6 are designed to provide multiple functions. Micrologix programmable controllers user manual p2 contents of this manual tab chapter title contents preface describes the purpose, background, and scope of this manual. Summary of contents for allenbradley micrologix 1500.

Need a replacement trip or would like to configure a non standard compact nsx circuit breaker. This manual describes operation of the micrologic 0, 1, 2, and 3 trip units only. Micrologic trip units can communicate with other devices if the optional. Similarly, by setting the devices so that each trip curve is clear from the device downstream of it will ensure discrimination between devices. Micrologic advanced protection ap troubleshooting guide. The thermal trip curves are calculated for selfcooled motors. Schneider electric powerpact h, j, and lframe circuit breakers. If logo continues to spin longer than ten seconds, fullfunction test kit has failed poweron test. Fdm121 display for lv circuit breaker user guide 2014.

Low voltage compact nsx100 to 630 fengsheng electric. For more information see the trip unit user guides 4894031001 and. They offer basic lsi protection micrologic 5 trip unit or lsi and groundfault protection g micrologic 6 trip unit. Micrologic series b trip system fullfunction features. Apr 15, 2016 tutorial for changing settings on micrologic h, j, or l frame circuit breakers via the lcd display. Square d offers the seals below to restrict access to trip unit once settings are selected. Micrologic 2 m trip units are adapted to protecting motorfeeders on standard applications. With over 35 years of experience and 180 employees, the company serves the entire province of quebec and offers customized solutions for its.

Configuring h, j or l frame micrologic trip units via display. Powerpact lframe and powerpact hjframe with micrologic 56 trip units. Current protection 0 overload and fault indications 4 measurements 5 trip history and prealarms 7. Includes all features listed for the micrologic power trip unit, as well as. Enhanced power measurements functions power quality measurements arequires neutral current transformer in 3o4w systems. Pe and px electronic trip circuit breakers with micrologic. Circuit breaker communication module bcm is installed. Compact nsx micrologic 567 electronic trip units user guide. Micrologic 2m and 6 em trip units can be used on any compact nsx circuit breaker. The micrologic 1 and 2 trip units are described in the compact nsx circuit breakers user manual.

It also provides guidance for potential solutions to restore power. Read these instructions carefully and look at the equipment to become familiar. Micrologic 5 and 6 electronic trip unitsuser guide. Micrologic trip unit settings schneider electric pages 1. Guide dexploitation des declencheurs micrologic 5 et 6. Business it groundbreakers for over 35 years micro logic is one of the 300 largest smes in quebec and is a leader in the province as a valueadded reseller of it solutions. Micrologic 5 and 6 electronic trip unitsuser guide unidades.

Micrologic 5, 6, trip units and micrologic vigi 7 trip units with display. Eolimasterpact nw 25 h1 three pole draw out circuit breaker with. Power quality measurements the trip unit is only available when the breaker type is electronic or stored energy. Micrologic control units 30 indication contacts 31. May 30, 2003 hello matjaz, i hope you have all the manuals for the micrologic device.

Moulded case circuit breakers micrologic trip units. Download the user manual schneider electric mafiadoc. Tutorial for configuring trip point amperage and delay settings on the micrologic 5. Automatic test mode, individual functiontest mode, and manual. Includes all features listed for micrologic standard trip unit, as well as. This manual describes operation of the micrologic 5 and 6 trip units. Micrologic trip units documents and downloads schneider electric. Square d added increased emcefi immunity to micrologic trip units built after december of 2005 following reports of nuisance trips during switching operations. Download documents for micrologic trip units micrologic electronic trip units are. Testing micrologic trip unit with full function test kit. Micrologic electronic trip unit micrologic trip unit accessories adjustable rating plug a is installed as standard on all micrologic trip unit orders. Instruction bulletin 4804094003 0301 cedar rapids, ia, usa k279 pe and px electronic trip circuit breakers with micrologic trip system series 6b retain for future use. Electronic trip insulated case circuit breakers manufactured by square d use the micrologic electronic trip system to sense overcurrents and trip the circuit breaker. Includes all features listed for the micrologic p power trip unit, as well as.

1547 1429 216 553 1447 977 1557 35 58 472 23 713 951 79 65 535 1428 1023 1586 1394 1128 692 868 102 600 1357 137 1205 904 475 722 464 623 1380 793 964 703